The Fluke 87V Ex Features: 

ATEX safety rating for use in Ex-zone 1 and zone 2
CAT IV 600 V electrical safety rating
Unique function for accurate voltage and frequency measurements on variable speed motor drives ( VSD’ s)
Large display with bright, two-level backlight makes the 87V Ex easy to read in all lighting environments
Built-in thermometer ( probe included)
True-rms ac voltage and current for accurate measurements on non-linear signals
4-1/ 2 digit mode for precise measurements ( 20, 000 counts)
Measure up to 1000 V and 10 A ( ac/ dc)
Frequency to 200 kHz and % duty cycle
Resistance, continuity and diode test
10, 000 ¼ F capacitance range for components and motor caps
Min/ Max-Average and Peak capture to record transients and variations automatically
Relative mode to remove test lead interference on resistance measurements
Auto and manual ranging for maximum flexibility
Analog bargraph for fast changing or unstable signals
Input Alert provides

Safety ratings : 
ATEX safety rating: II 2 G EEx ia IIC T4
Electrical safety rating: EN61010-1 CAT IV 600 V and CAT III, 1000 V

General Specifications
Voltage DC
Maximum voltage: 1000 V
Accuracy: ± ( 0.05 % + 1)
Maximum resolution: 10 ¼ V
Voltage AC
Maximum voltage: 1000 V
Accuracy: ± ( 0.7 % + 2) True-rms
AC bandwidth: 20 kHz
Maximum resolution: 10 ¼ V
Current DC
Maximum amps: 10 A ( 20 A for 30 seconds maximum)
Amps accuracy: ± ( 0.2 % + 2)
Maximum resolution: 0.01 ¼ A
Current AC
Maximum amps: 10 A ( 20 A for 30 seconds maximum)
Amps accuracy: ± ( 1.0 % + 2)
Maximum resolution: True-rms 0.01 ¼ A
Resistance
Maximum resistance: 50 M©
Accuracy: ± ( 0.2 % + 1)
Maximum resolution: 0.01 ©
Capacitance
Maximum capacitance: 9, 999 ¼ F
Accuracy: ± ( 1 % + 2)
Maximum resolution: 0.001 nF
Frequency
Maximum frequency: 200 kHz
Accuracy: ± ( 0.005 % + 1)
Maximum resolution: 0.001 Hz
Duty Cycle
Maximum duty cycle: 99.90 %
Accuracy: ± ( 0.2 % per khz + 0.1 % )
Maximum resolution: 0.10 %
Temperature
Range: -200.0 ° C to 1090 ° C ( -328 ° F to 1994 ° F) excluding probe
80BK Temperature Probe
Range: -40.0 ° C to 260 ° C ( -40 ° F to 500 ° F)
Accuracy: 2.2 ° C or 2 % whichever is greater
Conductance
Maximum conductance: 60.00 nS
Accuracy: ± ( 1.0 % + 10)
Maximum resolution: 0.001 nS
Diode
Range: 3 V
Resolution: 1 mV
Accuracy: ± ( 2 % + 1)
Duty Cycle Range
Accuracy: Within ± ( 0.2 % per kHz + 0.1 % )
Measurements restriction in Ex-hazardous area
Voltage: 65 V
Current: 5 A

Environmental Specifications
Operating Temperature
-20 ° C to + 50 ° C
Storage Temperature
-40 ° C to + 60 ° C
Humidity ( Without Condensation)
0 % to 80 % ( 0 ° C to 35 ° C) 0 % to 70 % ( 35 ° C to 50 ° C)
Operating Altitude
2000 m

Safety Specifications
Overvoltage category
EN 61010-1 to 1000 V CAT III, 600 V CAT IV
Agency Approvals
CSA, TÜ V
ATEX certification
Ex II 2 G EEx ia IIC T4
Agency Approvals
ZELM 05 ATEX 0274

Mechanical & General Specifications
Size
201 x 98 x 52 mm ( with holster)
Weight
12, 5 oz. ( 355 kg) with holster
Display ( Digital)
6000 counts updates 4/ sec. 19, 999 counts in high-resolution mod
Display ( Analog)
32 segments, updates 40/ sec.
Warranty
1 year
Battery Life
~ 400 hours typical without backlight
Shock
1 Meter drop per IEC 61010-1: 2001
Vibration
Per MIL-PRF-28800 for a Class 2 instrument


Untuk Info dan Pemesanan Hubungi :
DARMATEK
Contact: Subarkah
Telpon : 021-71031268
H P      : 081283804273/085774067221
Email  : subarkah18@yahoo.co.id
Gmail  : darmatek1@gmail.com
Pin BB : D2A771BD
Y M     : cs_darmatek
Web    : http://www.darmatek.net
Link    : http://darmatek.indonetwork.co.id
            http://darmatek01.blogspot.com




0 comments: