MILWAUKEE Mi-180 pH / ORP / Conductivity / TDS / NaCl / Temperature Laboratory Bench Meter
Mi180 pH / ORP / Conductivity / TDS / NaCl / Temperature Laboratory Bench Meter
Mi180 measures 6 different parameters: pH, ORP, EC, TDS ( Total
Dissolved Solids) , percentage of NaCl and temperature in a variety of
ranges.
pH calibration can be performed in 3 points selectable between 7
memorized buffers, to provide a very accurate calibration curve even
when testing different samples, where very wide differences in pH can be
found.
The auto-ranging feature for EC and TDS measurements automatically sets the resolution suitable to the tested sample.
All measurements can be temperature compensated at 20 or 25° C and the compensation coefficient is selectable by the user.
The automatic temperature compensation can also be disabled for
measuring the actual conductivity value. The stability indicator on the
LCD ensures accuracy. Conductivity readings are performed with the
4-ring probe supplied with the meter.
The GLP feature allows users to store and recall data on system status. PC compatible through an RS232 port or USB.
SPECIFICATIONS
pH Range -2.00 to 16.00 pH; -2.000 to 16.000 pH
mV Range ± 699.9 mV; ± 2000 mV
EC Range 0.00 to 29.99 µ S/ cm; 30.0 to 299.9 µ S/ cm; 300 to 2999 µ S/
cm; 3.00 to 29.99 mS/ cm; 30.0 to 200.0 mS/ cm; up to 500.0 mS/ cm
uncompensed EC*
TDS Range 0.0 to 14.99 mg/ l ( ppm) ; 15.0 to 149.9 mg/ l ( ppm) ; 150
to 1499 mg/ l ( ppm) ; 1.50 to 14.99 g/ l ( ppt) ; 15.0 to 100.0 g/ l (
ppt) ; up to 400.0 g/ l actual TDS* ( with 0.80 factor)
NaCl Range 0.0 to 400.0%
Temp Range -20.0 to 120.0° C / -4.0 to 248.0° F
pH Resolution 0.01 pH; 0.001 pH
mV Resolution 0.1 mV; 1 mV
EC Resolution 0.01 µ S/ cm; 0.1 µ S/ cm; 1 µ S/ cm; 0.01 mS/ cm; 0.1 mS/ cm;
TDS Resolution 0.01 mg/ l; 0.1 mg/ l; 1.0 mg/ l; 0.01 g/ l; 0.1 g/ l
NaCl Resolution 0.1%
Temp Resolution 0.1° C / 0.1° F
pH Accuracy ± 0.01 pH; ± 0.002 pH
mV Accuracy ± 0.2 mV; ± 1 mV
EC Accuracy ± 1% of reading ± ( 0.05 µ S/ cm or 1 digit)
TDS Accuracy ± 1% of reading ± ( 0.03 ppm or 1 digit)
NaCl Accuracy ± 1% of reading
Temp Accuracy ± 0.4° C / ± 0.8° F
Rel mV Offset ± 2000 mV
pH Calibration 1, 2 or 3 points calibration, with 7 memorized buffers ( pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01 and 12.45)
EC Calibration 1 point slope calibration with 6 memorized solutions: (
84 µ S/ cm, 1413 µ S/ cm, 5.00 mS/ cm, 12.88 µ S/ cm, 80.0 µ S/ cm,
111.8 mS/ cm)
NaCl Calibration 1 point, with MA9066 solution
Temp Calibration 2 point, at 0 and 50° C / 32 and 122° F
Temperature Compensation automatic or manual, from -20.0 to 120.0° C / -4.0 to 248.0° FF
Temperature Coefficient selectable from 0.00 to 6.00% / ° C ( EC and TDS only)
pH Electrodes & Temp Probe MA814DB/ 1 & MA917B/ 1 & MA831R ( included)
TDS Factor 0.40 to 0.80 ( default value is 0.50)
Log on demand up to 50 samples on each range ( pH, mV, EC, TDS, NaCl)
GLP last pH, EC, NaCl calibration data
PC Interface RS232 / USB Opto-isolated
Environment 0 to 50° C / 32 to 122° F; max RH 95%
Power supply 12 VDC power adapter ( included)
Dimensions 230 x 160 x 95 mm
Weight 0.9 kg
Untuk Info dan Pemesanan Hubungi :
DARMATEK
Contact: Subarkah
Telpon : 021-71031268
H P : 081283804273/085774067221
WA : 081932632003
WA : 081932632003
Email : subarkah18@yahoo.co.id
Gmail : darmatek1@gmail.com
Pin BB
: D2A771BD
Web : http://www.darmatek.net
Link : http://darmatek.indonetwork.co.id
http://darmatek01@blogspot.com
0 comments: