SEW 1824LP Digital LOOP/ PSC/ EARTH Tester
Loop Testers & Electrical Network
Analyzers
FEATURES
*Microprocessor-controlled.
*Measures Earth Resistance without the need for poles in the ground
or external measuring wires.
*Earth measurement uses the real earth current path and the current
generated by the electric network, without the need for any
disconnection.
*The Earth Resistance displayed is exactly the earth resistance that
the earth current will need to go through if an earth fault occurs.
( you do not need to add all the bonding points and connection
paths)
*Displays voltage supply at the transformer( Line to Neutral) , without
loading the transformer.
*Single one smart push button operation; ON, Scroll through results
and menus.
*Checks wiring integrity( LEDs) .
*Auto-off / Auto-ranging ( software range) .
*Color-coded test leads.
*Combined prospective short circuit current, loop, and earth tester.
*Loop test for L-E and PSC between L-N.
*Voltage test L-N.
*Display can be customized for large orders.
FEATURES
*Microprocessor-controlled.
*Measures Earth Resistance without the need for poles in the ground
or external measuring wires.
*Earth measurement uses the real earth current path and the current
generated by the electric network, without the need for any
disconnection.
*The Earth Resistance displayed is exactly the earth resistance that
the earth current will need to go through if an earth fault occurs.
( you do not need to add all the bonding points and connection
paths)
*Displays voltage supply at the transformer( Line to Neutral) , without
loading the transformer.
*Single one smart push button operation; ON, Scroll through results
and menus.
*Checks wiring integrity( LEDs) .
*Auto-off / Auto-ranging ( software range) .
*Color-coded test leads.
*Combined prospective short circuit current, loop, and earth tester.
*Loop test for L-E and PSC between L-N.
*Voltage test L-N.
*Display can be customized for large orders.
SPECIFICATIONS :
Loop impedance range L-E : 0.03-2000© ( Software Ctrl)
Test currents in each loop : 11.76A at 230V / 50Hz
Voltage measurement : 50 to 280V AC ( Sine)
Earth wire/ path
return resistance : 0.01-2000© ( Software Ctrl)
Neutral wire resistance : ( Not available, see 1826 NA)
Line wire resistance &
transformer windings : ( Not available, see 1826 NA)
PSC current( L-N) max : 6kA at 230Vac supply
PSC current( L-E) max : ( Not available, see 1826 NA)
Operating voltage : 230V± 20 at 50Hz Sine
Typical Accuracy
Loop impedance : 4% rdg ± 2dgt
PSC current : 10% rdg ± 5dgt
Voltage : 2% rdg ± 1dgt
Operating-temperature
-humidity : -10° C to + 40° C 80% Max.
relative humidity
Dimensions : 170( L) x 165( W) x 92( D) mm
Weight
( battery included) : Approx. 970g
Power source : 1.5V ( AA) x 8
Safety standard : EN 61010-1 CAT III 300V
EN 61326-1
Loop impedance range L-E : 0.03-2000© ( Software Ctrl)
Test currents in each loop : 11.76A at 230V / 50Hz
Voltage measurement : 50 to 280V AC ( Sine)
Earth wire/ path
return resistance : 0.01-2000© ( Software Ctrl)
Neutral wire resistance : ( Not available, see 1826 NA)
Line wire resistance &
transformer windings : ( Not available, see 1826 NA)
PSC current( L-N) max : 6kA at 230Vac supply
PSC current( L-E) max : ( Not available, see 1826 NA)
Operating voltage : 230V± 20 at 50Hz Sine
Typical Accuracy
Loop impedance : 4% rdg ± 2dgt
PSC current : 10% rdg ± 5dgt
Voltage : 2% rdg ± 1dgt
Operating-temperature
-humidity : -10° C to + 40° C 80% Max.
relative humidity
Dimensions : 170( L) x 165( W) x 92( D) mm
Weight
( battery included) : Approx. 970g
Power source : 1.5V ( AA) x 8
Safety standard : EN 61010-1 CAT III 300V
EN 61326-1
Untuk Info
dan Pemesanan Hubungi :
DARMATEK
Contact:
Subarkah
Telpon :
021-71031268
H P : 081283804273/085774067221
WA : 081932632003
WA : 081932632003
Email :
subarkah18@yahoo.co.id
Gmail : darmatek1@gmail.com
Pin BB :
D2A771BD
Web
: http://www.darmatek.net
Link : http://darmatek.indonetwork.co.id
http://darmatek01.blogspot.com
0 comments: