APPA 51 K-type Thermocouple (51, 52)

Toko Darmatek Indonesia

 



APPA 51 Thermometer K-type

Summary APPA 51
  • Measuring type: K-type thermocouple
  • Measurement range: -50~1300°C
  • Additional Features: display hold function
Features
  • K-type Thermocouple
  • Large LCD display (18.5mm)
  • 1°C or 0.1°C (1°F or 0.1°F) resolution; °C or °F resolution
  • Maximum Record; Reading hold function
  • Standard 9V battery; Protective holster with tilt stand
  • Bead probe included


Specifications
APPA 51
APPA 52
APPA 53II
APPA 55II
Measurement Range: K-type, -50°C~1300°C, -58°F~1999°F
+
+
N/A
N/A
K-type, -200°C~1372°C, -328°F~2501°F
N/A
N/A
+
+
J-type, -210°C~1200°C, -346°F~2192°F
Resolution: High: 0.1°C or 0.2°F, Low: 1°C or 1°F
+
+
N/A
N/A
0.1°C/0.1 K/0.2°F < 1000° , 1°C/1 K/2°F < 1000°
N/A
N/A
+
+
K-type Accuracy: ±(0.3%+1°C) at -50°C~1000°C, ±(0.3%+2°F) at -58°F~1832°F
+
+
N/A
N/A
±(0.5%+1°C) at 1000-1300°C, ±(0.5%+2°F) at 1832°F~1999°F
±(0.3%+1°C) at -200°C~-100°C, ±(0.3%+2°F) at -328°F~-148°F
N/A
N/A
+
+
±(0.1%+0.7°C) at -99.9°C~999.9°C, ±(0.1%+1.4°F) at-147.8°F~999.9°F
±(0.3%+1°C) at 1000°C—1372°C, ±(0.3%+2°F) at 1000°F~2501°F
J-type Accuracy: ±(0.3%+1.1°C) at -210°C~-100°C, ±(0.3%+2.2°F) at -346°F~-148°F
N/A
N/A
+
+
±(0.1%+0.8°C) at -99.9°C~999.9°C, ±(0.1%+1.6°F) at-147.8°F~999.9°F
±(0.3%+1°C) at 1000°C~1200°C, ±(0.3%+2°F) at 1000°F~2192°F
Accuracy: T1-T2
N/A
+ (K-type)
N/A
+ (K/J-type)
±(0.3% of T1-T2 reading + 2.0°C), ±(0.3% of T1-T2 reading + 4.0°F)
Temperature Coefficient: 0.15(Spec. Acc)/°C, <18°C or >28°C
+
+
N/A
N/A
0.1(Spec. Acc)/°C, <18°C or >28°C
N/A
N/A
+
+
Data logging Capacity: 16,000 records
N/A
N/A
+
+
PC interface software: Optical RS-232 interface cable with Win DTM 50 software
N/A
N/A
+ (Option)
+ (Option)

General
APPA 51
APPA 52
APPA 53II
APPA 55II
Input: K-type thermocouple
+
+
+ (J-type option)
+ (J-type option)
Sampling Rate: 2.5 times/sec
+
+
2 times/sec
1 times/sec
Display: 3 digit (1999 count) LCD, full annunciators
+
+
N/A
N/A
Display: Triple 4 digit (9999 count) LCD, full annunciators
N/A
N/A
+
+
Overload Indication
"1" or "-1"
"1" or "-1"
"----"
"----"
Low Battery Indication
+
+
+
+
Selectable Auto Power Off: you can select an APO of OFF, 10, 20, 30, 40, 50 and 60 minutes
N/A
N/A
+
+
Operating Temperature: 0°C~50°C, ≤80% RH
+
+
+
+
Storage Temperature: -20°C~60°C
+
+
+
+
Input Protection: 60V DC or 24Vrms AC maximum
+
+
+
+
Power Requirement: Single 9V battery (NEDA 1604 or IEC 6F22)
+
+
+
+
Battery Life: in hours (Alkaline battery)
250
250
90
90
Size: 64mm(W) x 160mm (L) x 26 mm(H), without holster
+
+
+
+
Size: 74mm(W) x 170mm (L) x 39 mm (H), with holster
+
+
+
+
Weight: in grams (with holster)
430
430
430
430
Included with instrument: Type 50BK bead thermocouple, ZnC battery (installed), Protective holster, belt clip and manual
+
+
(50BK x 2)
+
+
(50BK x 2)

Scope of delivery APPA 51
  • Thermometer K-type thermocouple APPA 51
  • Type 50BK bead thermocouple
  • ZnC battery (installed)
  • Protective holster
  • Belt clip
  • Manual

0 comments: