HANNA HI-93414 Turbidity and Free/Total Cl2 Portable Meter

Toko Darmatek Indonesia

HANNA HI 93414 Turbidity and Free/Total Cl2 Portable Meter
with CAL CHECK™ and Fast Tracker™, EPA Compliant
  • High accuracy at low ranges   
  • Exclusive chlorine CAL CHECK™ calibration validation
  • Exclusive Fast Tracker™ system
  • User replaceable light source
  • Two, three or four point turbidity calibration
  • USB and RS232 PC connectivity
  • GLP features
  • Logging for up to 200 readings
  • User friendly, backlit  display with guidance codes
  • Auto-off
  • Battery % on startup
  • Continuous current time on display
Hanna HI 93414 measures the most important parameters of drinking water: turbidity and free/total chlorine. Designed for water quality measurements, HI 93414 provides reliable and accurate readings on low turbidity and chlorine values. The HI 93414 meets and exceeds the requirements of USEPA and Standard Methods both for turbidity and colorimetric measurements.

This instrument incorporates an optical system which guarantees accurate results. The optical system, consisting of a tungsten filament lamp, three detectors (scattered, transmitted for turbidimeter range and one for colorimeter range), and a narrow band interference filter @ 525 nm assures long term stability and minimizes stray light and color interferences. It also compensates for variations in intensity of the lamp, making no need for frequent calibration. The 25 mm round cuvettes made from special optical glass guarantee repeatability and consistency of measurements.


Turbidity measurements can be made in the 0.00 to 1000 NTU (Nephelometric Turbidity Units) range. The instrument has an EPA compliance reading mode which rounds readings to meet EPA reporting requirements. Depending on the measured sample and needed accuracy, normal measurement, continuous measurement or signal averaging measurement can be selected. Free or total chlorine measurements can be made in the 0.00 to 5.00 mg/L (ppm) range.


At startup, the meter displays the percentage of remaining battery life and, if too low, a 'low battery' warning message is displayed.

With the powerful CAL CHECK™ function, performance of the instrument can be validated at any time by using the exclusive HANNA ready-made NIST traceable standards. Calibration can be performed at any time for turbidity and colorimetric range. For turbidity, a two, three or four-point calibration is available using supplied (<0.1, 15, 100 and 750 NTU adjustable calibration points) or user prepared standards. For colorimeter measurements, a one-point calibration can be performed.

HI 93414 has complete GLP (Good Laboratory Practice) functions that allow traceability of the calibration conditions. The last calibration points, time and date can be checked at the touch of a button. HI 93414 has a user-friendly interface with an easy to read, large (LCD). Displayed codes guide the user step by step with routine operation and through calibration. Confirmation and error acoustic signals aid the user during instrument operation.


For advanced field applications, the HI 93414 is equipped with Fast Tracker™—Tag Identification System (T.I.S.) that makes data collecting and management simpler than ever. Fast Tracker™ allows users to record the time and location of a specific measurement or series of measurements.

With it’s logging function, up to 200 measurements along with it’s tagged locations can be stored in internal memory and consulted at any time. Data can be later transferred to a PC via RS232 or USB interface and HANNA HI 92000 software (optional).

Order Information:


HI 93414-01 (115V) and HI 93414-02 (230V) is supplied with sample cuvettes and caps (5), calibration cuvettes for turbidimeter, calibration cuvettes for colorimeter, silicone oil, cuvette wiping tissue, scissors, batteries, AC adapter, instructions and rugged carrying case.

Specification Hanna HI-93414:



Range 
Turbidity 0.00 to 9.99; 10.0 to 99.9 and 100 to 1000 NTU
Free and
Total Cl2
0.00 to 5.00 mg/L
Resolution Turbidity 0.01 NTU from 0.00 to 9.99 NTU; 0.1 NTU from 10.0 to 99.9 NTU; 1 NTU from 100 to 1000 NTU
Free and
Total Cl2
0.01 mg/L from 0.00 to 3.50 mg/L; 0.10 above 3.50 mg/L
Accuracy @25°C Turbidity ±2% of reading plus 0.02 NTU
Free and
Total Cl2
±0.03 mg/L ±3%  of reading (whichever is greater)
Method Turbidity Ratio Nephelometric Method (90°), ratio of scattered and transmitted light; adaptation of the USEPA Method 180.1 and Standard Method 2130 B
Free and Total Cl2 adaptation of the USEPA Method 330.5 and Standard Method 4500-Cl G. The reaction between chlorine and DPD reagent causes a pink tint in the sample.
Standards Turbidity <0.1, 15, 100 and 750 NTU
Free and Total Cl2 1 mg/L free chlorine, 1 mg/L total chlorine
Calibration Turbidity two, three or four-point calibration
Free and Total Cl2 one-point calibration
Light Detector Turbidity silicon photocell
Free and
Total Cl2
silicon photocell with 525 nm narrow band interference filter
Turbidity Range
Selection

automatic
Stray Light
< 0.02 NTU
Measuring Mode
normal, average, continuous
Light Source
tungsten filament lamp
Lamp Life
greater than 100,000 readings
Log Memory
200 records
Serial Interface
USB or RS 232
Environment
0°C (32°F) to 50°C (122°F); max 95% RH non-condensing
Power Supply
1.5V AA alkaline batteries (4) or AC adapter; auto-off after 15 minutes of non-use
Dimensions / Weight
224 x 87 x 77 mm (8.8 x 3.4 x 3.0”) / 512 g (18 oz.)

0 comments:

HANNA HI-98703 Turbidity Meter

Toko Darmatek Indonesia

HANNA HI 98703 Turbidity Meter
with Fast Tracker™ Technology, EPA Compliant
  • High accuracy at low ranges (below 0.05 NTU)
  • Two, three or four point calibration
  • USB and RS232 PC connectivity
  • Log up to 200 records
  • GLP Features
  • User friendly, backlit  display with guidance codes
  • Battery % on startup
  • Continuous current time on display
The HI 98703 meets and exceeds the requirements of the USEPA Method 180.1 for wastewater and Standard Method 2130 B for drinking water. The instrument has an EPA compliance reading mode which rounds readings to meet EPA reporting requirements. Users will appreciate the accuracy and sensitivity of this instrument, particularly at very low turbidity levels.
This instrument incorporates complete GLP (Good Laboratory Practice) functions that allow traceability of the calibration conditions. The last calibration points,  time and date can be checked at the touch of a button.
With it’s logging function, up to 200 measurements along with it’s tagged locations can be stored in internal memory and consulted at any time. Data can be later transferred to a PC via RS232 or USB interface and HANNA HI 92000 software (optional).

Exclusive Fast Tracker™

For advanced field applications, the HI 98703 is equipped with Fast Tracker™—Tag Identification System (T.I.S.) that makes data collecting and management simpler than ever. Fast Tracker™ allows users to record the time and location of a specific measurement or series of measurements.

Order Information:

HI 98703-01 (115V), HI 98703-02 (230V) and HI 98703-03 (AUS plug) are supplied with sample cuvettes and caps (5), HI 98703-11 calibration cuvettes, HI 93703-58 silicone oil, cuvette cleaning cloth, batteries, AC adapter, instruction manual and rugged carrying case.

Specification 
Hanna HI-98703:



Range
0.00 to 9.99; 10.0 to 99.9 and 100 to 1000 NTU
Range Selection
automatic
Resolution
0.01 NTU from 0.00 to 9.99 NTU; 0.1 NTU from 10.0 to 99.9 NTU; 1 NTU from 100 to 1000 NTU
Accuracy @25°C
±2% of reading plus 0.02 NTU
Repeatability
±1% of reading or 0.02 NTU, whichever is greater
Stray Light
< 0.02 NTU
Light Detector
silicon photocell
Light Source
tungsten filament lamp
Lamp Life
greater than 100,000 readings
Method
Ratio Nephelometric Method (90°), ratio of scattered and transmitted light; Adaptation of the USEPA Method 180.1 and Standard Method 2130 B
Measuring Mode
normal, average, continuous
Turbidity Standards
<0.1, 15, 100 and 750 NTU
Calibration
two, three or four-point calibration
Log Memory
200 records
PC Connectivity
USB or RS232
Environment
up to 50°C (122°F); RH max 95% non-condensing
Power Supply
1.5V AA alkaline batteries (4) or AC adapter; auto-off after 15 minutes of non-use
Dimensions / Weight
224 x 87 x 77 mm (8.8 x 3.4 x 3.0”) / 512 g (18 oz.)

0 comments:

Hach 2100Q Portable Turbidity Meter

Toko Darmatek Indonesia

Hach 2100Q Portable Turbidity Meter

Description:


The Hach 2100Q Portable Turbidity Meter offers unsurpassed ease of use and accuracy in turbidity measurement.

Features

  • Single standard calibration reduces calibration and handling time
  • On-screen assisted verification ensures instrument is performing correctly
  • RST mode for precise measurement in rapidly settling samples
Description

Easy Calibration and Verification

The Hach 2100Q Portable Turbidity Meter provides confidence your measurements are right every time. On-screen assisted calibration and verification save you time and ensure accuracy. With an easy-to-follow interface, complicated manuals are not needed to perform routine calibrations. Single-standard RapidCal calibration offers a simplified solution for low level measurements.

Simple Data Transfer

Data transfer with the Hach 2100Q portable turbidity meter is simple, flexible, and doesn't require additional software when used with the optional USB + Power module. All data can be transferred to the module and easily downloaded to your computer with a USB connection, providing superior data integrity and availability. With two different module options, you can customize connectivity and power to meet your unique needs.

Accurate for Rapidly Settling Samples

The Hach 2100Q Portable Turbidity Meter incorporates an innovative Rapidly Settling Turbidity mode to provide accurate, repeatable measurements for difficult to measure, rapidly settling samples. An exclusive algorithm that calculates turbidity based on a series of automatic readings eliminates redundant measurements and estimating.

Convenient Data Logging

Up to 500 measurements are automatically stored in the instrument for easy access and backup. Stored information includes: date and time, operator ID, reading mode, sample ID, sample number, units, calibration time, calibration status, error messages and the result.

Optical System for Precision in the Field

The two-detector optical system compensates for color in the sample, light fluctuation, and stray light, enabling analysts to achieve laboratory-grade performance on a wide range of samples, even under difficult site conditions.

Specification Hach 2100Q:


Notable Specifications:

Measurement Method: Ratio turbidimetric determination using a primary nephelometric light scatter signal (90) to the transmitted light scatter signal.
Regulatory: Meets EPA Method 180.1
Light Source: Tungsten filament lamp
Range: 0 to 1000 NTU (FNU)
Accuracy: +/-2% of reading plus stray light from 0 to 1000 NTU
Repeatability: +/-1% of reading, or 0.01 NTU (FNU), whichever is greater
Resolution: 0.01 NTU on lowest range
Stray Light:< 0.02 NTU (FNU)
Signal Averaging: Selectable on/off
Detector: Silicon photovoltaic
Reading Modes (user selectable): Normal (Push to Read); Signal Averaging; Rapidly Settling Turbidity
Data Logger: 500 records
Power Requirement: 110-230 VAC, 50/60 Hz (with Power or USB+Power module); 4 AA alkaline batteries; Rechargeable NiMH (for use with USB+Power module)
Operating Conditions: Temperature: 0 to 50 C (32 to 122 F); Relative Humidity: 0 to 90% @ 30 C, 0 to 80% @ 40 C, 0 to 70% @ 50 C, non-condensing
Storage Conditions: -40 to 60 C (-40 to 140 F), instrument only
Interface: Optional USB
Instrument Enclosure Rating: IP67 (closed lid, battery compartment excluded)
Protection Class: Power Supply: Class II
Certification: CE certified
Sample Required: 10mL (0.3 oz.)
Sample Cells: 60mm x 25mm (2.36" x 1") borosilicate glass with screw cap
Dimensions: 22.9cm x 10.7cm x 7.7cm (9.0" x 4.2" x 3.0")
Weight: 527g (1.16 lb.) without batteries; 618g (1.36 lb.) with four AA alkaline batteries

0 comments:

Eutech TN-100 Waterproof Portable Turbidity Meter

Toko Darmatek Indonesia

Eutech Waterproof Portable TN100 Turbidity Meter

Product Features

  • IP67 Waterproof and Dustproof - Cleaning and maintenance is simple. It floats!
  • Automatic Push-Button Calibration (4 points) for unprecedented full-range accuracy
  • Sturdy Carrying Kit complete with 4 calibration standards, 3 empty cuvettes, batteries and comprehensive instruction manual
  • Power-saving feature allows over 1200 measurements to be taken with a single set of AAA alkaline batteries
  • Large Easy-to-Read Display for optimum viewing of measurements with user-friendly message codes for easy troubleshooting
  • Meets Performance Criteria as specified by ISO 7027 (DIN EN 27027) method
The microprocessor-based waterproof TN100 meter is an easy-to-use turbidimeter that meets the rigor of rugged field applications. It is a "must -have" for anyone monitoring turbidity on the go. Using an Infrared light source, it delivers laboratory accuracy with a resolution of 0.01 NTU across an extended range of up to 20 NTU (Nephelometric Turbidity Units).

Specification Eutech TN-100:



Product Specification Description
Principle of Operation Nephelometric non-ratio (conformance to
 ISO 7027 and DIN EN 27027)
Turbidity Range 0 to 1000 NTU
Resolution 0.01 NTU (0 to 19.9 NTU)
0.1 NTU (20.0 to 99.9 NTU)
1 NTU (100 to 1000 NTU)
Accuracy ± 2% of reading ± 1 LSD for 0 to 500 NTU
± 3% of reading ± 1 LSD for 501 to1000 NTU
Repeatability ± 1% of reading or ± 0.01 NTU
No. of Calibration Points 4 points (automatic)
Response Time < 6 seconds for full step change
Calibration Standards 0.02 NTU; 20.0 NTU; 100 NTU; 800 NTU
Standardization EPA-approved polymer-based primary standards
Light Source Life > 1,000,000 tests
Light Source Infrared-emitting diode (850nm wavelength)
Special Functions Auto-Ranging; Self-diagnostic
Power Requirements 4 x 1.4V batteries, > 200 hours

0 comments:

Extech TB-400 Portable Turbidity Meter

Toko Darmatek Indonesia

Extech TB400 Portable Turbidity Meter
  • Measures the turbidity of various water solutions
  • Data hold function, Min/Max calculations with record/recall feature
  • Battery-powered, compact and easy to use
Description Extech TB400:

Turbidity refers to the cloudiness or haziness of a fluid, caused by a large number of individual particles that are invisible to the naked eye. The measurement of turbidity is a key test of water quality.
The Extech TB400 Portable Turbidity Meter comes complete with all of the accessories in order to conveniently test the turbidity of municipal water, consumable water and other aqueous solutions where fluid clarity is important.
Powered by six AAA batteries, the Extech TB400 turbidity meter is portable, allowing for instant measurement and analysis on-site, rather than collecting samples to be taken back to a laboratory. It also has Data Hold and Min/Max Calculations with Record/Recall functions built in.

Key Features
  • Microprocessor-based circuitry assures high accuracy and repeatable readings
  • Requires only a 10mL sample size
  • 2-point calibration
  • Splash-proof front panel
  • Battery operated for field and on-site testing
  • Data Hold and Min/Max record/recall
  • Auto power off
  • Contact Extech or your local lab supply for refills on the standard solution
Specification Extech TB-400:
  • Range (NTU) – 0.00 to 50.00 NTU, 50 to 1000 NTU (Nephelometric Turbidity Unit)
  • Resolution – 0.01 NTU
  • Accuracy - ±5% or ±0.5 NTU, whichever is greater
  • Light Source – LED 850nm
  • Standard – Designed to meet ISO 7027
  • Response Time - <10 seconds
  • Dimensions – 6.1 x 3.0 x 2.4” (155 x 76 x 62mm)
  • Weight – 11.3oz (320g)
Supplied Accessories
  • Extech TB400 Portable Turbidity Meter
  • 0 NTU Standard Solution Test Bottle
  • 100 NTU Standard Solution Test Bottle
  • Cleaning Solution (Distilled Water)
  • 2x Test Bottles and Covers
  • Cleaning Cloth
  • 6x AAA Batteries
  • Hard Carrying Case

0 comments:

LUTRON TU-2016 TURBIDITY METER

Toko Darmatek Indonesia

Jual LUTRON TU-2016 TURBIDITY Meter dengan harga murah, diskon dan cari produk Lutron lainnya dari kategori Turbidity. Gratis biaya pengiriman untuk wilayah Jakarta dan dapat dikirim ke seluruh Indonesia. Dapatkan hanya di toko online Darmatek, belanja online mudah dan aman. Kami sebagai pusat penjualan LUTRON TU-2016 TURBIDITY METER melayani pengiriman gratis ongkir untuk wilayah Jakarta dan sekitarnya, silahkan hubungi sales kami di HP : 0812-8380-4273, WA : 0819-3263-2003 untuk info harga dan stock.

Description :

Turbidity Meter
Model : TU-2016
* Range : Auto range, two ranges, 0.00 to 50.00 NTU, 50 to 1,000 NTU.
* Resolution : 0.01 NTU/1 NTU.
* Accuracy : 5 % F.S. or 0.5 NTU, which ever is greater.
* Light source : LED, 850 nm.
* Record Max, Min value.
* Power : 1.5 V battery (UM-4/AAA) x 6 PCs.
* 0 NTU and 100 NTU Calibration solution are included.
* Designed to meet ISO 7027.

0 comments:

Tenmars TM-902 Lan Cable Tester

Toko Damatek Indonesia


- Detects opens shorts miswires and split pairs on the twisted pair cabling on the LAN cable.
- Measures length.
- Auto backlit.
- Auto power off.

The backlit LCD screen displays graph wire-map, opens, shorts, miswires, split pairs and the remote ID number all on one screen. Using multiple remote ID up to 8 locators to test on RJ-45 (UTP, STP) LAN cable.

Model:
Connector type
RJ-45
Cable category
LAN cable (UTP, STP),cable.
Wire-map test
Detects opens, shorts, miswires, split pairs
Length test
up to 255 M (836 ft)
Length resolution
0.1 m (ft)
Length units
Meter and Foot
Accuracy
+/- 10% + 1.0M (3 ft)
Operating temp. and RH
5 to 40 ยบC, below 80% RH.
Storage temp. and RH
-10 to 60ยบC, below 70%.
Power
9V batteryx1
1.5V battery x 6
Dimensions (L x W x H)
130 x 56 x 38mm.
156 x 73 x 35mm
Weight
About 160g
About 170g

Accessories
User’s manual, battery, Carrying case,
Test Cable x1, Remote ID (1) x1

0 comments: