Hach 2100Q Portable Turbidity Meter

Toko Darmatek Indonesia

Hach 2100Q Portable Turbidity Meter

Description:


The Hach 2100Q Portable Turbidity Meter offers unsurpassed ease of use and accuracy in turbidity measurement.

Features

  • Single standard calibration reduces calibration and handling time
  • On-screen assisted verification ensures instrument is performing correctly
  • RST mode for precise measurement in rapidly settling samples
Description

Easy Calibration and Verification

The Hach 2100Q Portable Turbidity Meter provides confidence your measurements are right every time. On-screen assisted calibration and verification save you time and ensure accuracy. With an easy-to-follow interface, complicated manuals are not needed to perform routine calibrations. Single-standard RapidCal calibration offers a simplified solution for low level measurements.

Simple Data Transfer

Data transfer with the Hach 2100Q portable turbidity meter is simple, flexible, and doesn't require additional software when used with the optional USB + Power module. All data can be transferred to the module and easily downloaded to your computer with a USB connection, providing superior data integrity and availability. With two different module options, you can customize connectivity and power to meet your unique needs.

Accurate for Rapidly Settling Samples

The Hach 2100Q Portable Turbidity Meter incorporates an innovative Rapidly Settling Turbidity mode to provide accurate, repeatable measurements for difficult to measure, rapidly settling samples. An exclusive algorithm that calculates turbidity based on a series of automatic readings eliminates redundant measurements and estimating.

Convenient Data Logging

Up to 500 measurements are automatically stored in the instrument for easy access and backup. Stored information includes: date and time, operator ID, reading mode, sample ID, sample number, units, calibration time, calibration status, error messages and the result.

Optical System for Precision in the Field

The two-detector optical system compensates for color in the sample, light fluctuation, and stray light, enabling analysts to achieve laboratory-grade performance on a wide range of samples, even under difficult site conditions.

Specification Hach 2100Q:


Notable Specifications:

Measurement Method: Ratio turbidimetric determination using a primary nephelometric light scatter signal (90) to the transmitted light scatter signal.
Regulatory: Meets EPA Method 180.1
Light Source: Tungsten filament lamp
Range: 0 to 1000 NTU (FNU)
Accuracy: +/-2% of reading plus stray light from 0 to 1000 NTU
Repeatability: +/-1% of reading, or 0.01 NTU (FNU), whichever is greater
Resolution: 0.01 NTU on lowest range
Stray Light:< 0.02 NTU (FNU)
Signal Averaging: Selectable on/off
Detector: Silicon photovoltaic
Reading Modes (user selectable): Normal (Push to Read); Signal Averaging; Rapidly Settling Turbidity
Data Logger: 500 records
Power Requirement: 110-230 VAC, 50/60 Hz (with Power or USB+Power module); 4 AA alkaline batteries; Rechargeable NiMH (for use with USB+Power module)
Operating Conditions: Temperature: 0 to 50 C (32 to 122 F); Relative Humidity: 0 to 90% @ 30 C, 0 to 80% @ 40 C, 0 to 70% @ 50 C, non-condensing
Storage Conditions: -40 to 60 C (-40 to 140 F), instrument only
Interface: Optional USB
Instrument Enclosure Rating: IP67 (closed lid, battery compartment excluded)
Protection Class: Power Supply: Class II
Certification: CE certified
Sample Required: 10mL (0.3 oz.)
Sample Cells: 60mm x 25mm (2.36" x 1") borosilicate glass with screw cap
Dimensions: 22.9cm x 10.7cm x 7.7cm (9.0" x 4.2" x 3.0")
Weight: 527g (1.16 lb.) without batteries; 618g (1.36 lb.) with four AA alkaline batteries