GW Instek GFC-8131H Frequency Counter
Features
- Frequency and Period Measurement
- High Resolution at Both High and Low Frequency
- 0.01Hz~1.3GHz Frequency Range(GFC-8131H)
- 10mV rms High Sensitivity
- 100nHz Resolution for 1Hz Input
- Variable Trigger Level Control
Description :
The GFC-8000 Series performs virtuallyall of the counting measurements required in laboratories, in terms of bothperiod and frequency. A bright red 8 digit LED display with an includedoverflow indicator provides a clear view.
Both models feature a stable timebase with a maximum resolution of 100nHz and 10nS at 1Hz for frequency andperiod measurement, respectively.
Gate time can be configured for fast response(5 digits/10ms) or accuracy (7 digits/s) for more control. For high frequencyneeds, the GFC-8270H can operate at up to 2.7GHz. The GFC-8000 Series featureseasy operation with a simple front panel interface, suitable for both portableand bench-top use.
Both models feature a stable timebase with a maximum resolution of 100nHz and 10nS at 1Hz for frequency andperiod measurement, respectively.
Gate time can be configured for fast response(5 digits/10ms) or accuracy (7 digits/s) for more control. For high frequencyneeds, the GFC-8270H can operate at up to 2.7GHz. The GFC-8000 Series featureseasy operation with a simple front panel interface, suitable for both portableand bench-top use.
DISPLAY
|
|
8 digits with Hz, kHz, MHz, GHz, s, ms, μs, and
overflow
|
|
GATE TIME
|
|
Variable from 10ms to 10s, or 1 period of input
depending on whichever is greater
|
|
ACCURACY
|
|
±(resolution ± timebase error)
|
|
CHANNEL A
|
|
Range
|
DC coupling: 0.01Hz ~ 120MHz
AC coupling: 30Hz ~ 120MHz
|
Sensitivity
|
10mV typical, 50mV maximum
|
Coupling
|
AC or DC, selectable
|
Filter
|
Low pass, selectable in or out for channel A
(-3dB point, nominal 100kHz)
|
Impedance
|
1MΩ // 40pF
|
Attenuator
|
1/1 or 1/20dB
|
Trigger Level
|
-2.5VDC ~ +2.5VDC
|
Adjustment Resolution
|
For frequency measurement, the maximum resolution
is 100nHz for 1Hz and 0.1Hz for 100MHz inputs respectively.
For period measurement, the maximum resolution is
10ns for 1Hz input, and 0.1x10-15s for 100MHz inputs respectively.
|
Display Accuracy
|
7 digits for 1 sec gate time
6 digits for 100ms gate time
5 digits for 10ms gate time
|
Period Range
|
8ns ~ 100ns (at least 7 digits displayed per gate
time)
|
CHANNEL B
|
|
Range
|
50MHz ~ 2.7GHz for GFC-8270H
50MHz ~ 1.3GHz for GFC-8131H
|
Sensitivity
|
<50mVrms
(10mVrms typical) for GFC-8270H
<40mVrms
(10mVrms typical) for GFC-8131H
|
Coupling
|
AC only
|
TIME BASE
|
|
Aging Rate
|
1ppm per month
|
Temperature
|
5ppm, 23°C + 5°C
|
Line Variation
|
0.005ppm for + 10% variation
|
POWER SOURCE
|
|
AC 100V/120V/220V/230V ±10%, 50/60Hz
|
|
DIMENSIONS & WEIGHT
|
|
230(W) × 95(H) × 280(D) mm
Approx. 2.2kg
|
0 comments: