Jual Opti Science GFPIII General Fluorescence Probe

Toko Darmatek Indonesia

 

Keterangan:

 
Application
• Detection of GFP, green fluorescent protein
• Detection of most other fluorescent proteins
• Detection of specialized fluorescent
compounds down to the ppb range
• Transgenic crop research & development
• Detect genetically modified organisms
• Gene expression studies
• Detection & measurement of contaminants
• Pesticide / Chemical spray analysis
• Parts inspection

Features
Lightweight, Hand-Held Design Optimized
for Field Work
• Discrete sample measurement - solid, plant,
animal tissue or liquid
• Single sampling or continuous monitoring rates
from1 per second to 1 per minute.
• User Changeable source & detect filter modules
• Bright Color Graphic data display
• 8 Hrs use on two AA rechargeable batteries
• Data logging up for up to 2 gigabytes of data
• Stand Alone Operation- No P.C. Required

The GFPIII is a general purpose modulated fiber optic probe
fluorometer designed for a variety of measurement
applications. It is available with a choice of excitation and
detection modules to meet most fluorescence measurement
requirements including popular selections such as;
Chlorophyll, Rhodamine, Fluorescein, GFP, and most other
Fluorescent protein compounds. Custom modules can also be
created for special applications, with filters available from the
UV to the near infrared range.

As a hand-held, field portable instrument, the light weight and easy to carry GFPIII incorporates on-board data logging
and a bright TFT color graphics touch sensitive display screen for system parameters and data display. Up to two
gigabytes of data, traces, calibration tables, and user settings can be stored on the instrument. Rechargeable AA batteries
will commonly allow the instrument to run for up to eight hours before recharging. A second set of batteries are included
with the instrument. A metal leaf clip is provided for those doing transgenic and GFP detection studies as well.
Opti-Sciences has designed this instrument to provide the most reliable results available by including temperature
compensation and multi-point calibration capabilities over the measuring range selected.

References for GFP Meter ( all versions) .
Li1 J., Brunner A.M., Meilan R., Strauss S.H. ( 2009) Stability of transgenes in trees:
expression of two reporter genes in poplar over three field seasonsTree Physiol ( 2009) 29
( 2) : 299-312
Li1 J., Brunner A.M., Meilan R., Strauss S.H.1, ( 2008) Matrix attachment region elements
have small and variable effects on transgene expression and stability in field-grown
PopulusArticle first published online: 7 SEP 2008 DOI: 10.1111/ j.1467-
7652.2008.00369.x Plant Biotechnology Journal Volume 6, Issue 9, pages 887896,
December 2008
Stuart M., Dignan C., McClary D., Golder Associates ( NZ) Ltd, Dunedin, NZ. Ltd,
Takapuna, NZ. ( 2008) Evaluation of marine response tools: Subtidal containment and
treatment system MAF Biosecurity New Zealand Technical Paper No: 2010/ 20 Prepared
for MAF Biosecurity New Zealand By ISBN 978-0-478-37081-2 ( print) ISBN 978-0-478-
37082-9 ( online) ISSN 1179-5832 ( print) ISSN 1179-5840 ( online) December 2008
Millwood R.J., Moon H. S., and Stewart C. N., ( 2008) Fluorescent Proteins in Transgenic
Plants Reviews in Fluorescence 2008, Reviews in Fluorescence, Volume 2008, 387-403,
DOI: 10.1007/ 978-1-4419-1260-2_16
Leckie B. M. and Stewart C.N., ( 2008) Agroinfiltration as a technique for rapid assays for
evaluating candidate insect resistance transgenes in plants From the issue entitled " Special
Issue: Plant biotechnology in support of the Millennium Goals ( Volume I) " Plant Cell
Reports Volume 30, Number 3, 325-334, DOI: 10.1007/ s00299-010-0961-2
Palumbo RE., and Veilleux R.E., ( 2007) Variation of GFP expression in diploid and
tetraploid transgenic potato American Journal of Potato Research Volume 84, Number 5,
393-401, DOI: 10.1007/ BF02987185
Matthew D.
Halfhill R., Millwood R.J, Stewart C.N., ( 2004) Green Fluorescent Protein

Quantification in Whole Plants , Reginald J. and C. Neal Transgenic Plants: Methods and
Protocols Methods in Molecular Biology, 2004, Volume 286, IV, 215-225, DOI:
10.1385/ 1-59259-827-7: 215
Millwood R.J. , Halfhill1 M.D. , Harkins D. Russotti R., and Stewart, Jr. C.N.
( 2003) Instrumentation and Methodology for Quantifying GFP Fluorescence in
Intact Plant Organs, UNC Greensboro, Greensboro, NC, 1NC State University, Raleigh,
NC, and Opti-Sciences, Tyngsboro, MA, USA BioTechniques 34: 638-643 ( March 2003)
Halfhill M.D., Millwood R.J. , Rufty T.W. , Weissinger A.K. and Stewart C.N. ( 2004)
Spatial and temporal patterns of green fluorescent protein ( GFP) fluorescence during leaf
canopy development in transgenic oilseed rape, Brassica napus L. Plant Cell Reports
Volume 22, Number 5, 338-343, DOI: 10.1007/ s00299-003-0696-4


Untuk Info dan Pemesanan Hubungi :
DARMATEK
Contact: Subarkah
Telpon : 021-71031268
H P    : 081283804273/085774067221
Email  : subarkah18@yahoo.co.id
Gmail  : darmatek1@gmail.com
Pin BB : D2A771BD
Y M    : cs_darmatek
Web    : http://www.darmatek.net
Link   : http://darmatek.indonetwork.co.id
         http://darmatek01.blogspot.com

0 comments: